Flue liner system I-1

Flue liner system I-1

System is designed to exhaust combustion products by natural draught from heating appliances. System is used for relining of existing chimneys.

Chimney system for particular cases must be selected according to the documentation of the heating appliance manufacturer, chimney installation guide and national legal acts.

Fuel Oil, gas, solid fuels
Operating temperature ≤ 600 °C
Steel Stainless steel EN 1.4404
Wall thickness When dn from 80 to 200 mm – 0,5, 0,6, 0,8, 1,0 mm
When dn from 230 to 550 mm – 0,6, 0,8, 1,0 mm
When dn from 600 to 900 mm – 0,8, 1,0 mm
Pressure class N1 – Natural draught
Sootfire resistance G – resistant
Distance to combustible materials ≥ 5001 mm
Condensate resistance W – designed for wet operating conditions
Certificate no. 1397-CPD-0182
1397-CPD-0183
Designation code EN 1856-2 T600-N1-W-Vm-L50050-G(500)
EN 1856-2 T600-N1-W-Vm-L50060-G(500)
EN 1856-2 T600-N1-W-Vm-L50080-G(500)
EN 1856-2 T600-N1-W-Vm-L50100-G(500)
1 The actual minimum distance to combustible material from the outer surface of a connecting flue pipe (for flue liners isn’t applied) must be defined according to the designation of the product, as described in their marking, and national legal acts. If the legal acts and chimney designation indicate different distances to the combustible materials it is necessary to follow a bigger distance. 

Catalogue Download PDF
Instructions Download PDF
Declaration of performance Download PDF
Certificate Download PDF

Where to purchase?

We are looking for new partners